SANKING | INDUSTRIAL PIPING STANDARDS
Start With the Material and the Service
PVC-U and PVC-C (CPVC): ISO 15493
PP, including PP-H (PPH): ISO 15494
PVDF: ISO 10931
Use this map to find the industrial piping standard to review. Before approving a pipe, fitting, or valve, match the project requirements to evidence for its exact model, size, resin, manufacturing configuration, and applicable tests. A material name alone cannot establish conformity.
ISO scopes / Seven project inputs / Material choices / Model-level evidence / BOM and RFQ / FAQ
What Each Industrial Piping Standard Covers
| Standard | System scope |
|---|---|
| ISO 15493 | Metric-series PVC-U, PVC-C, and ABS components and systems for above-ground industrial applications. Covers requirements for components such as pipes, fittings, and valves. |
| ISO 15494 | Metric-series components and systems for above- and below-ground industrial applications. PP is one of the materials covered, alongside PB, PE, PE-RT, and PE-X. Check the requirements for the proposed PP-H pipes, fittings, valves, and joints. |
| ISO 10931 | PVDF components and systems for above-ground industrial applications. Covers components such as pipes, fittings, and valves. A high-purity service adds its own acceptance criteria. |
Industrial service or water supply? ISO 1452 covers PVC-U water supply and pressure drainage and sewerage. ISO 15877 and ISO 15874 address PVC-C and PP systems, respectively, for hot and cold water installations within buildings. For a process-water line inside a plant, use the service description and project piping specification to decide which requirements govern.
Use SANKING's Industrial Plastic Piping Solutions to start from your application, whether it is a chemical process line, semiconductor utility, or industrial wastewater system.
Seven Inputs That Decide the Piping System
- Medium. Identify the process fluid and any cleaning or flush liquids the line will see.
- Concentration. Give the range and any changes during dosing, cleaning, or startup.
- Temperature. Record normal, peak, and cleaning temperatures.
- Pressure. Pair the pressure with temperature for each operating case. Flag surge or vacuum if expected.
- Purity. Specify the fab or project limits and the test, cleaning, and packaging records it requires.
- Connection. Record pipe OD, dimensional series, valve end type, and the approved joint method.
- Automation. Define manual, on/off, or modulating duty. For actuated valves, give the available utilities, control signal, and required position on loss of power or air.
Check the complete assembly at the actual operating conditions. Use pressure-temperature data for the proposed size and configuration. Check chemical compatibility for all wetted parts, including seats, seals, gaskets, and the joint system. The lowest applicable rating governs the assembly.
Where PVC-U, CPVC, PP-H, and PVDF Fit
PVC-U and PVC-C (CPVC). Screen PVC-U for water treatment and wastewater equipment at moderate temperatures. For warmer process water or compatible chemical service, compare PVC-C at the required operating pressure and temperature. Check the socket series and the approved joining system before pairing pipe and fittings with PVC ball valves or CPVC ball valves.
PP-H. For chemical transfer or an industrial wastewater skid, check the PP-H resin and seal compatibility against the actual fluid and concentration. Match the pipe and fittings to the connection offered for the exact PPH ball valve configuration.
![]() |
SANKING PPH True Union Ball Valve Confirm socket-fusion or butt-weld ends on the quoted drawing, along with the seal material and service rating. |
PVDF. For a semiconductor ultrapure water (UPW) loop or a selected corrosive stream, check the exact grade and assembly. Where purity limits apply, request the test scope for the wetted configuration, such as extractables results and any required cleanliness or packaging records. Compare PVDF ball valve configurations against those requirements.
![]() |
SANKING Electric PVDF True Union Ball Valve This valve illustrates electric on/off actuation. Check the actuator configuration and request any required purity documentation for the quoted wetted assembly separately. |
For a side-by-side comparison of valve bodies and seals, see the PVC, CPVC, PPH, and PVDF valve selection matrix.
What to Verify Before Approving a Model
Match the drawing and material records. Check the part number, drawing revision, size, ends, resin grade, and wetted materials against the offer. Request the applicable manufacturing records, production site, and batch traceability where the project requires them.
Check what the test report covers. Match its standard edition, test method, acceptance criteria, and tested configuration to the proposed item. If the supplier relies on a family-level qualification, ask how it covers that size and construction. A report for a socket-end valve needs a documented basis before it can support a flanged version. Confirm which body and seat tests the project calls for. Check separate valve standards if specified.
Approve the joints as well as the parts. Check socket dimensions and approved cement, fusion end compatibility and the qualified procedure, or the flange pattern and gasket, as applicable. Match the drawing to the pipe and fitting on both sides of the valve.
A material change can change the whole installation. Replacing a solvent-cement CPVC branch with a fusion-joined PP-H branch can change joining tools, installer qualification, supports and thermal movement, valve end dimensions, and spare parts. Include those changes and any required requalification when comparing the installed cost.
What to Put on the BOM and RFQ
Line and service. Line or tag ID, project specification and edition, medium and concentration, pressure-temperature cases, and purity criteria.
Each component. Pipe, fitting, or valve model and quantity, size and dimensional series, resin and wetted materials, joint type and end dimensions, rating, and drawing revision. Include pipe wall series or SDR where applicable.
Acceptance. List required declarations, test reports, and traceability for each item. For an actuated valve, add actuator model, supply, control signal, and required failure position.
Request a Standards Map From SANKING
Send the medium, concentration, temperature, pressure, purity requirement, material, and project specification for a standards map.
Industrial Plastic Piping Standards FAQ
Does a CPVC marking establish ISO 15493 conformity?
CPVC identifies the material family. Ask for conformity evidence that covers the quoted item, dimensional series, size, and construction under the required edition.
Does ISO 15494 cover PP-H piping?
Use ISO 15494 as the industrial PP reference. Confirm the homopolymer grade, component configuration, and supporting documents for the PP-H system you are buying.
Does ISO 10931 qualify a PVDF valve for semiconductor UPW?
UPW approval requires the fab's purity criteria and evidence for the actual wetted configuration. If the project invokes SEMI F57, check its requirements and the applicable test and packaging documentation separately.
Can a pipe test report cover a valve or fitting of the same resin?
Check the scope on the report. A pipe test supports the pipe in its stated scope. A valve or fitting needs evidence for its own design and the requirements that apply to it.
Which ISO edition should go on the purchase order?
Use the edition and amendments specified by the project. If the spec lists only an ISO number, confirm the edition with the project owner before issuing the purchase order.
Official Standards References
ISO 15493:2003 and 2016 amendment · ISO 15494:2015 and 2020 amendment · ISO 10931:2005 and 2015 amendment